Operating instructions
Precision/ compact balances and
platform scales
KERN 572/573/KB/DS/FKB/KBJ
Version 7.2
10/2014
GB
572/573/KB/DS/FKB/KBJ-BA-e-1472
Vista de pagina 0
1 2 3 4 5 6 ... 41 42

Indice de contenidos

Pagina 1 - Operating instructions

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Tel: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-so

Pagina 2 - KERN 572/573/KB/DS/FKB/KBJ

2.3 KERN KB/KBJ KERN KB 120-3N KB 240-3N KB 360-3N Readability (d) 0.001 g 0.001 g 0.001 g Weighing range (max) 120 g 240 g 360 g Taring range (sub

Pagina 3

KERN KB 1200-2N KB 2000-2N KB 2400-2N KB 3600-2N Readability (d) 0.01 g 0.01 g 0.01 g 0.01 g Weighing range (max) 1 200 g 2 000 g 2 400 g 3 600 g Tar

Pagina 4 - 1 MODE - MENUE

KERN KB 10000-1N KB 10k0.05N Readability (d) 0.1 g 0.05 g Weighing range (max) 10 000 g 10 000 g Taring range (subtractive) 10 000 g 10 000 g Re

Pagina 5

KERN KB 650-2NM KB 6500-1NM KBJ 650-2NM Accuracy class II II II Readability (d) 0.01 g 0.1 g 0.01 g Verification value (e) 0.1 g 1 g 0.1 g Weighing r

Pagina 6 - 2 Technical data

2.4 KERN DS KERN DS 3K0.01S DS 5K0.05S DS 8K0.05 DS 10K0.1S Readability (d) 0.01 g 0.05 g 0.05 g 0,1 g Weighing range (max) 3 000 g 5 000 g 8 000 g

Pagina 7

KERN DS 16K0.1 DS 20K0.1 DS 30K0.1 Readability (d) 0.1 g 0.1 g 0.1 g Weighing range (max) 16 000 g 20 000 g 30 000 g Taring range (subtractive) 16 0

Pagina 8

KERN DS 36K0.2 DS 30K0.1L DS 36K0.2L DS 60K0,2 Readability (d) 0.2 g 0.1 g 0.2 g 0.2 g Weighing range (max) 36 000 g 30 000 g 36 000 g 60 000 g Tarin

Pagina 9

KERN DS 65K0.5 DS 100K0.5 DS 150K1 Readability (d) 0.5 g 0.5 g 1 g Weighing range (max) 65 000 g 100 000 g 150 000 g Taring range (subtractive) 65 0

Pagina 10

KERN DS 65K1M Accuracy class II Readability (d) 1 g Verification value (e) 10 g Weighing range (max) 65 000 g Minimum load (Min) 50 g Taring range (s

Pagina 11

2.5 KERN FKB KERN FKB 6K0.02 FKB 8K0.05 FKB 16K0.05 FKB 16K0.1 Readability (d) 0.02 g 0.05 g 0.05 g 0.1 g Weighing range (max) 6 000 g 8 000 g 16

Pagina 12

GB KERN 572/573/KB/DS/FKB/KBJ Version 7.2 10/2014 Operating instruction Precision/compact balances and platform scales Table of contents: 1 MODE

Pagina 13

KERN FKB 36K0.1 FKB 36K0.2 FKB 65K0.2 FKB 65K0.5 Readability (d) 0.1 g 0.2 g 0.2 g 0.5 g Weighing range (max) 36 000 g 36 000 g 65 000 g 65 000 g Tar

Pagina 14

KERN FKB 8K0.1M FKB 65K1M Accuracy class II II Readability (d) 0.1 g 1 g Verification value (e) 1.0 g 10 g Weighing range (max) 8 000 g 65 000 g Min

Pagina 15

3 Fundamental information (general) It is essential to read through and observe the complete operating instructions before in-stalling and commissio

Pagina 16

4 Fundamental safety information 4.1 Observe the information in the operating instructions Carefully read this operation manual before setup and c

Pagina 17

6 Unpacking, installation and commissioning 6.1 Place of installation, place of use The balance is constructed in such a way that reliable weighing

Pagina 18

6.4 Battery operation FKB  To insert the batteries (6 x 1.5 V) remove the battery compartment cover. Remove it with the help of a coin.

Pagina 19

6.8 Adjusting (go to 7.2.6) Using a precision weight, the accuracy of the balance can be checked at any time and adjusted. Warning: With verified b

Pagina 20

6.8.2 Adjustment of the balance KBJ with internal adjustment weight After expiring of the warm-up time (wait > 299s), the balance KBJ is autom

Pagina 21

7 Operation 7.1 Display control panel Keyboard ON / OFF Print weighing result in MODE: No / descending in % and counting mode: Form ref

Pagina 22

7.2 Operation 7.2.1 Weighing with Tare 7.2.2 Count – Selection reference piece 7.2.3 Percent % 7.2.4 Formula Weighing 7.2.5 Tolerance Weig

Pagina 23 - 5 Transport and storage

7 Operation ... 28 7.1 Display control

Pagina 24

572/573/KB/DS/FKB/KBJ-BA-e-1472 30

Pagina 25

7.2.6 Adjust 7.2.7 Preselect Tare 7.2.8 Auto Tare active 7.2.9 Filter / Speed 7.2.10 Auto Off active 7.2.11 Variable Factor 7.2.12 Preselect Unit

Pagina 26

572/573/KB/DS/FKB/KBJ-BA-e-1472 32

Pagina 27

7.2.13 Animal weighing:  Activate via mode/animal weigh. Y/N (4xMode)  Put container without measured object on the weighing surface and tare 

Pagina 28 - 7 Operation

7.2.15 Contents of the form printout: MODE / PRINTER / PRINTERFORM Var 1 Type xx = Gross MODE Var 1 Row xx XXxx MODE Var 1 Type 02 = Gross Var 1

Pagina 29

7.3 Display background illumination After having switched on your balance and the zero display, press the „MODE“ button to select the menu point „Ba

Pagina 30

7.5 RS 232 C Data output via interface RS 232 C RS 232 C Data output via interface RS 232 C General information As a condition for the data transfer

Pagina 31

7.5.1 Description of the data transfer Structure of each data transfer: Bit-Nr. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 B* N N N B B B B B 0

Pagina 32

7.7 Underfloor weighing Objects which, because of their size or shape, cannot be put on the scale, can be weighed by means of underfloor weighing.

Pagina 33

8 Maintenance, upkeep, disposal 8.1 Cleaning Please disconnect the device from the operating voltage before cleaning. Only use a cloth dampened w

Pagina 34 - Printerform

1 MODE - MENUE Models 572 / KB / DS / FKB / non-verifiable: Important! The modified settings - as well as the adjustment - must be stored when s

Pagina 35

9 Troubleshooting The balance should be switched off for a short time following an interruption in the pro-gramme sequence and disconnected from th

Pagina 36

10 Declaration of conformity KERN & Sohn GmbH D-72322 Balingen-Frommern Postfach 4052 E-Mail: [email protected] Tel: 0049-[0]7433- 9933-0 Fax:

Pagina 37

KERN & Sohn GmbH D-72322 Balingen-Frommern Postfach 4052 E-Mail: [email protected] Tel: 0049-[0]7433- 9933-0 Fax: 0049-[0]7433-9933-149 Internet

Pagina 38 - ! NOTE !

Models 573-NM; KB-NM; DS-M; FKB-M; KBJ-NM: Important! The modified settings - as well as the adjustment - must be stored when switching-off, via

Pagina 39

2 Technical data 2.1 KERN 572 KERN 572-30 572-31 572-32 572-33 Readability (d) 0.001 g 0.001 g 0.001 g 0.01 g Weighing range (max) 240 g 300 g 420

Pagina 40 - 9 Troubleshooting

KERN 572-35 572-37 572-39 572-43 Readability (d) 0.01 g 0.01 g 0.01 g 0.1 g Weighing range (max) 2400 g 3000 g 4200 g 10000 g Taring range (subtracti

Pagina 41 - Signature

KERN 572-45 572-49 572-55 572-57 Readability (d) 0.05 g 0.1 g 0.05 g 0.1 g Weighing range (max) 12000 g 16000 g 20000 g 24000 g Taring range (subtrac

Pagina 42

2.2 KERN 573 KERN 573-34NM 573-46NM Accuracy class II II Readability (d) 0.01 g 0.1 g Verification value (e) 0.1 g 1 g Weighing range (max) 650 g 65