Kern-sohn MBB 15K2DM Manual de usuario

Busca en linea o descarga Manual de usuario para Escamas Kern-sohn MBB 15K2DM. KERN & SOHN MBB 15K2DM User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
email: info@kern-sohn.com
Phone: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
Operating instructions
Baby weighing scale
KERN MBB-M
Version 1.4
02/2013
GB
MBB-M-BA-e-1314
Vista de pagina 0
1 2 3 4 5 6 ... 33 34

Indice de contenidos

Pagina 1 - Baby weighing scale

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-

Pagina 2 - KERN MBB-M

10 MBB-M-BA-e-1314 5 Appliance overview 213 4 5 1. Weighing pan 2. Bubble level 3. Display unit 4. Stand (optional) 5. Wall bracket

Pagina 3

MBB-M-BA-e-1314 11 6 Overview of displays Display Designation Description 1 0 Zeroing display Should the balance not display exactly zero

Pagina 4 - 1 Technical Data

12 MBB-M-BA-e-1314 7 Keyboard overview Button Designation Function ON/OFF-switch Turn on/off Zero setting key Balance will be reset to 0.0

Pagina 5 - 0297

MBB-M-BA-e-1314 13 8 Transportation & Storage 8.1 Testing upon acceptance When receiving the appliance, please check packaging immediately

Pagina 6

14 MBB-M-BA-e-1314 9 Unpacking, Setup and Commissioning 9.1 Installation Site, Location of Use The balances are designed in a way that rel

Pagina 7

MBB-M-BA-e-1314 15 9.3 Scope of supply  Balance  Power unit (in conformity with EN 60601-1), including fuse and LED  Wall bracket  Oper

Pagina 8

16 MBB-M-BA-e-1314 3. Then screw in the corresponding locking screw to achieve a tight fit. 4. Use the supplied knurled screws to attach t

Pagina 9 - 4 Basic Safety Precautions

MBB-M-BA-e-1314 17 9.6 Stand assembly (optional)  Use the 4 screws to attach the stand to the bottom of the scale.  Remove the two latera

Pagina 10 - 5 Appliance overview

18 MBB-M-BA-e-1314 9.8 Rechargeable battery operation (optional) When an optional rechargeable battery is used, proceed as follows: On model

Pagina 11 - 6 Overview of displays

MBB-M-BA-e-1314 19  Carefully insert the rechargeable battery block and insert plug into connection CN 3 Ensure that the cables are not squee

Pagina 12 - 7 Keyboard overview

2 MBB-M-BA-e-1314 GB KERN MBB-M Version 1.4 02/2013 Operating instructions Baby weighing scale Table of Contents 1 Technical Data ...

Pagina 13

20 MBB-M-BA-e-1314 9.9 Connecting the power supply Power is supplied by the external power unit which also serves to isolate the mains supply

Pagina 14

MBB-M-BA-e-1314 21 10 Menu overview  Start balance by pressing OFFON  Press for 3 sec., “SETUP“ will be displayed.  Select paramete

Pagina 15

22 MBB-M-BA-e-1314 11 Operation 11.1 Weighing  0  Start balance by pressing OFFON The balance carry out a segment test, then the program

Pagina 16

MBB-M-BA-e-1314 23  The balance is able to only store one taring value.  When the balance is unloaded the saved taring value is displayed w

Pagina 17

24 MBB-M-BA-e-1314 12 Error messages Display Description Underload Weight on weighing pan is too low. Please increase weight. If the erro

Pagina 18

MBB-M-BA-e-1314 25 13 Service, maintenance, disposal 13.1 Cleaning Disconnect the unit from the mains power supply prior to cleaning. Please

Pagina 19

26 MBB-M-BA-e-1314 14 Instant help In case of a fault in the program sequence, the balance should be shortly switched off. The weighing proces

Pagina 20

MBB-M-BA-e-1314 27 15 Verification Verified scales bear a verification mark or one or more seals affixed by the Bureau of Standards or the man

Pagina 21 - 10 Menu overview

28 MBB-M-BA-e-1314   Press HOLD repeatedly until “CAL 0“ appears.   Press TARE, the display will show a numeric value.  Then

Pagina 22 - 11 Operation

MBB-M-BA-e-1314 29 15.2 Adjustment controls and seals After a verification the balance is sealed at the indicated positions. Verification of th

Pagina 23

MBB-M-BA-e-1314 3 9 Unpacking, Setup and Commissioning ... 14 9.1 Installation Site, Locatio

Pagina 24 - 12 Error messages

30 MBB-M-BA-e-1314 Position of the adjustment switch: Position of the adjustment switch State 1. to left Not documented 2. concentric

Pagina 25

MBB-M-BA-e-1314 31 15.4 Navigation in the menu  With the balance switched on, keep the button depressed for approx. 3 sec until "SET

Pagina 26 - 14 Instant help

32 MBB-M-BA-e-1314 Press the [HOLD] and [TARE] buttons to make the selection * default setting * * * * * *

Pagina 27 - 15 Verification

MBB-M-BA-e-1314 33 Description: Weighing unit: kg Partition steps, weighing range (max.) and readout (d) Multi-range balance/ single-range ba

Pagina 28

34 MBB-M-BA-e-1314 15.5 Verification validity period (current status in G)  Personal scales in hospitals 4 year  Personal scales if not

Pagina 29

4 MBB-M-BA-e-1314 1 Technical Data KERN MBB 15K5M MBB 15K2DM Display 6-digit Weighing range (max) 15 kg 6 kg; 15 kg Minimum load (Min) 100 g

Pagina 30

MBB-M-BA-e-1314 5 2 Declaration of conformity Declaration of conformity: See separate document showing serial number of device CE marking:

Pagina 31

6 MBB-M-BA-e-1314 “Electro-medical appliance“ with attachment for type B Device protection category II Dispose of old appliances

Pagina 32

MBB-M-BA-e-1314 7 3 Basic Information (General) Weighing instruments have to be verified for the purposes stated below in accordance with

Pagina 33

8 MBB-M-BA-e-1314 3.3 Improper Use Do not use these scales for dynamic weighing processes. Do not leave permanent load on the balance

Pagina 34

MBB-M-BA-e-1314 9 4 Basic Safety Precautions 4.1 Pay attention to the instructions in the Operation Manual Carefully read this operation manu