Kern-sohn RPB D Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Escamas Kern-sohn RPB D. KERN & SOHN RPB D User Manual [en] [de] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 33
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Phone +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
Instruction Manual
Price computing scales
KERN RPB_D
Version 2.5
05/2014
GB
RPB_D-BA-e-1425
Vista de pagina 0
1 2 3 4 5 6 ... 32 33

Indice de contenidos

Pagina 1 - Price computing scales

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Phone +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-so

Pagina 2 - KERN RPB_D

3 Basic Information (General) 3.1 Proper use The balance you purchased is intended to determine the weighing value of material to be weighed. It is

Pagina 3

4 Basic Safety Precautions 4.1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and comm

Pagina 4 - 1 Technical data

6 Unpacking, Setup and Commissioning 6.1 Installation Site, Location of Use The balances are designed in a way that reliable weighing results are ac

Pagina 5

6.3 Transport screw Remove the transport screw essential (available only at 6 kg model) To loosen the transportation lock, unscrew transporta

Pagina 6 - 2 Appliance overview

6.3.2 Scope of delivery / serial accessories: • Balance, see chap. 2 • Mains adapter • Protective cover • Instruction Manual 6.4 Mains connect

Pagina 7

6.7 Adjustment As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated - in compliance

Pagina 8

4. Ensure that there are no objects on the weighing plate. Wait for stability display, then press . The required adjustment weight is shown. 5.

Pagina 9

6.8 Verification UUGeneral: According to EU directive 90/384/EEC balances must be officially verified if they are used as follows (legally controll

Pagina 10

6.8.1 Adjustment controls and seals Possible seals: enforced, and or 1. Seal mark 1 2. Cover 3. Verification switch 4. Verification wi

Pagina 11 - 5 Transport and storage

6.9.1 Service mode This overview of the service parameters is merely for checking the parameters set by the appropriate Bureau of Standards. No chang

Pagina 12

GB KERN RPB_D Version 2.5 05/2014 Instruction Manual Price computing scales Contents 1 Technical data ...

Pagina 13

Overview for service parameter: Factory settings are marked by [*]. Function Settings  Description   CAL F0 Adjustment function, see chpt

Pagina 14

CAL F6 Display internal resolution XXX A-d CoUntS CAL F7 Coin Interval size currency Min Coin 1* Always use this setting Min Coin

Pagina 15

7 Operation Mode 7.1 Turn on/off  To turn on/off confirm forward at the underneath on the right of the scale and keep pressed for a little while.

Pagina 16

8 Weighing with price determination As soon as the goods to be weighed are placed on the balance and the basic price has been set the price is calcul

Pagina 17 - UUGeneral:

8.1.1 Unit switch over €/kg to €/100 g The following parameters should be set for this: To carry out these settings please proceed as fo

Pagina 18

Press (should „oFF“ not be displayed, press ) Press (should „on“ not be displayed, press ) Press again (should „on“ not be displ

Pagina 19

8.2 Memory for basic price (PLU = Price look up) The balance is able to store up to 10 basic prices. Save:  Enter basic price via the numeric keys

Pagina 20

Before calling-up an other PLU, the displayed basic price has to be deleted by . Calculating the change:  Press at the display sales price (

Pagina 21 - RPB_D-BA-e-1425 21

9 Additional useful functions 9.1 AUTO CLEAR Enable:  To enable the AUTO-CLEAR function press ; the arrow above „“AUTO CLEAR“ will start flashi

Pagina 22 - 7 Operation Mode

9.3 AUTO POWER OFF To save the rechargeable battery (option), the automatic switch-off function can be activated, switch-off time selectable after 0,

Pagina 23

10 RS 232 interface ... 30 10.1 Technical data ...

Pagina 24

10 RS 232 interface 10.1 Technical data RS 232 connection to output of weighing data ASCII code Baud rate 600, 1200, 2400, 4800, 9600 8 data bits No

Pagina 25

11 Service, maintenance, disposal 11.1 Cleaning Before cleaning, please disconnect the appliance from the operating voltage. Please do not use aggres

Pagina 26

12 Instant help In case of an error in the program process, briefly turn off the balance and disconnect from power supply. The weighing process must

Pagina 27

13 Declaration of -Conformity KERN & Sohn GmbH D-72322 Balingen-Frommern Postfach 4052 E-Mail: [email protected] Tel: 0049-[0]7433- 9933-0 Fax:

Pagina 28

1 Technical data Models without vertical display: KERN RPB 6K1DM RPB 15K2DM RPB 30K5DM Weighing range (max) 3 kg / 6 kg 6 kg / 15 kg 15 kg / 3

Pagina 29

Models with post-mounted display: KERN RPB 6K1DHM RPB 15K2DHM RPB 30K5DHM Weighing range (max) 3 kg / 6 kg 6 kg / 15 kg 15 kg / 30 kg Readabili

Pagina 30 - 10 RS 232 interface

2 Appliance overview Models without vertical display: Models with post-mounted display: 1. Weighing plate / rechargeable battery compartment (u

Pagina 31

Weight Basic price Sales price 2.1 Overview of display Operator and secondary display (standard on the backside of models without post-mou

Pagina 32 - 12 Instant help

Display weight Here, the weight of your goods is displayed. Indicator  next to symbol displays: Battery very low GROSS�Gross weight NET Net weight

Pagina 33 - Declaration of -Conformity

2.2 Keyboard overview Bubble level Selection Function ~ 3 Numerical keys, PLU-keys • Delete • Save basic price (press and hold key for a